• The professional
    battery package factory
    • Product search
  • HomeAbout UsProductsCompany CapabilityContact With UsTechnical Service
  • Company Profile Culture
    Li-ion batteries Chargers E-kits for bikes
    • Products
      • Li-ion batteries
      • Chargers
      • E-kits for bikes
    • contact us
    • Wuxi Doctor Power Technology Co.,Ltd
      ADD:Building 701-1 ,No. 311 Fangcheng avenue , Xishan district , Wuxi city , China

      Phone: 0086-15962676200

      Mail:kaidy.yu@doctor-power.com

      Web: www.doctor-power.com 

      Skype: Kaidy.yu1


    • Products
      Current:HomeProducts All products
      • DPH-3613
      • Product Name:DPH-3613
      • Product Code:
      • Views:1977
      • Product details:
      • 1.Characteristic(@25 degree)

         

        No.

        Item

        Unit

        Value


        Remark

        1.1   Basic Characteristic

        01

         

        Cell model

        -

        18650-2.6Ah/3.7V

        Samsung , Panasonic or Chinese cells

        02

        Combination Mode

        -

        5P10S


        03

        Nominal Capacity

        Ah

        13

        5A Discharging test

        04

        Minimum Capacity

        Ah

        12.8


        05

        Rated Voltage

        V

        36


        06

        Over Charge Voltage

        V

        42

        Max 42.5V

        07

        Over  Discharge Voltage

        V

        27.5

        Cells over discharge 2.75V

        08

        Low Temperature Discharge  Ending Voltage

        V

        27.5

        -20 degree

        09

        Standard Charge Current

        A

        2.0


        10

                       Max. Charge Current

        A

        5

        -

        11

        Standard  Discharge Current

        A

        10


        12

        Max Continuous Discharge Current

        A

        15


        13

        Battery Case

        -

        ABS


        14

        Weight

        kg

        3

        About

        15

        Operating Temperature

        degree

        0~+45 degree

        Charge

        -20~ +55 degree

        Discharge

        16

        Life Time

        Cycle

        Above 1000


        2.2   BMS Characteristic

        01

         

        Over Charge Protect Voltage

        V

        4.2 +/- 0.025

        Single Series

        02

        Over Charge Protect Delay Time

        S

        1 +/- 0.3


        03

        Over Charge Release Condition

        -

         

        Discharge


        04

        Over Discharge Protect Voltage

        V

        2.750 +/- 0.05

        Single Series

        05

        Over Discharge Protect Delay Time

        mS

        320 +/- 45


        06

        Over Discharge Release Condition

        -

        Charge


        07

        Discharge Over Current Protect

        A

        45 +/- 5


        08

        Discharge Over Current Delay Time

        mS

        320 +/- 45


        09

        Discharge Over Current Release Condition

        -

        Release From Load


        10

        Short Circuit Protect Condition

        -

        External Short Circuit


        11

        Short Circuit Protect Delay Time

        uS

        180-550


        12

        Short Circuit Protect Release Condition

        -

        Release From Load


        13

        Equalization Start Voltage

        V

        4.2 +/- 0.025

        -

        14

         

        Equalizing Current

        mA

        40 +/- 5


        15

        High Temperature Protect

        degree

        70 +/- 5

         

        Discharge

        16

         

        Low Temperature Protect

        degree

        -

        -

         

        2.Test Requirement 

        2.1 Standard test condition 

        Battery Pack to be tested should be new battery pack within one month after shipment from our factory and the battery pack should not be cycled more than five times before the test. Unless otherwise specified, test and measurement should be done under these conditions:

        Temperature : 15~25 degree

        Relative Humidity: 45%~75%RH

        Atmospheric Pressure : 86kPa~106kPa

        2.2 Test & Measurement Equipment Requirement

        Dimension Measurement Instrument :

        1)The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.   

        2) Battery test system should have current accuracy within +/- 0.1%, voltage accuracy within +/- 0.5% , & time accuracy within +/- 0.1%.

        3) Temperature measurement accuracy of instruments should be within +/- 0.5 degree.

        4) Voltmeter:

        Standard class specified in national standard or more sensitive class, with internal impedance not less than 10 KΩ.

        5) Ammeter:

        Standard class specified in national standard or more sensitive class. Total resistance including ammeter and wire is less than 0.01Ω.

        6) Impedance shall be measured by a sinusoidal alternating current method (AC 1kHz LCR). Resistance is not a constant value according to the change of temperature and state of charge, and related to lead length and capacity.

        7) All test equipments and measuring instruments should be passed inspection of calibration organization.

        2.3 Standard charging method 

        At standard test condition, charge battery pack with standard charge current (0.2C5A) under constant current mode to charge ending voltage, then charge battery pack with charge ending voltage under constant voltage mode till charge current declines to 0.02C5A or less.

        2.4 Appearance Test Standard

        There shall be no such defect as scratch, flaw, crack, rust, leakage, or which may adversely affect commercial value of battery.


        3. Electrical properties

        3.1 Capacity @ 0.2C5A

        After standard charging, laying the battery pack 0.5~1.0h, then discharging at 0.2C5A to ending voltage, record the discharging time.

        Criteria:  above 300min

        3.2 Capacity @ 1C5A

        After standard charging, laying the battery pack 0.5~1.0h, then discharging at 1C5A to ending voltage, record the discharging time.

        Criteria:  above 54min

        3.3  Discharge at low temperature

        After standard charging, laying the battery pack at -20+/-2 degree for 16h, then discharging at 0.2C5A to low temperature discharge ending voltage, record the discharging time.

         Criteria:  above 180min

        3.4 Discharge at high temperature

          After standard charging, laying the battery pack at 60 +/- 2 degree for 2h , then discharging at 0.2C5A to ending voltage, record the discharging time.

         Criteria:  above 270min

        3.5  Cycle Life

        After standard charging, laying the battery pack 0.5~1.0h, then discharging at 0.2C5A to ending voltage,laying the battery pack 0.5~1.0h again, Repeat these steps above till two consecutive discharging time less than 210 minutes,record the cycle count.

        Criteria:  above 800times

        3.6 charge retention

        After standard charging, laying the battery pack 28 days, then discharging at 0.2C5A to ending voltage, record the discharging time.

        Criteria:  above 270 min

        4.Environmental Suitability 

        4.1  Constant Damp Heat Test

        After standard charging, keeping the battery pack in environment of 40 +/- 2 degree / 90%~95%RH for 48h, then laying the battery pack in standard test condition for 2h.

        Criteria: No explosion or smoking.

        4.2  Vibration Test

        After standard charging, fix the battery pack to vibration table, vibrate the battery pack in each axis of  X, Y, Z with frequency sweep rate of 1oct/min for 30 minutes under the vibration frequency and amplitude of both 10Hz~30Hz/0.38mm & 30Hz~55Hz/ 0.19mm.

        Criteria: No explosion, smoking or leakage. Battery pack's voltage not lower than rated voltage.

        4.3 Continuous Shock Test

        After standard charging, fix the battery pack to shock table, shock the battery pack in each axis of X,Y,Z with these condition:

        Acceleration :100m/s2

        Pulse lasting time :16ms

        Shock times per minutes :40~80 times

        Shock times :1000+/-10 times

        Criteria: No explosion. No smoking. No leakage.

        5. Safety Characteristic

        These safety Characteristic test is applied only to the cell used in this battery pack.

        5.1  Thermal shock

        Put the battery pack in the oven. Raise the temperature of the oven with 5 +/- 2 degree per minute to 130 +/- 2 degree and lasts 30 minutes.

        Criteria: No fire, no explosion.

        5.2 Over Discharge

        Discharge the battery pack with constant current of 0.2 C5A to discharge ending voltage, then connect the battery pack to  external load of 300 ohm for 24 hours.

        Criteria: No fire, no explosion, no smoke, no leakage.

        5.3  Short Circuit

        After standard charging, connect the anode pole to cathode pole of the battery pack's discharge terminal by lead with impedance less than 100mOhm, keep 1 hour.

        Criteria: No fire, no explosion, no smoke, no leakage.

        5.4 Over Charge

        Charge the battery pack with constant current of 0.2 C5A to charge ending voltage, then charge the battery pack with 10V of charge ending voltage,and with the constant voltage 10 hours,or until the cell voltage will not rise .

        Criteria: No fire, no explosion.

        6. Storage and Shipment Requirement 

         Item

          Criteria

        Storage temperature

         

        Short period(less than 1 month)

        -10~45 degree

        Medium period (less than 3 month)

        -10~35 degree

        Long period (more than 3 month)

        0~30 degree

         Relative Humidity

        Less than 75%RH

         State of Charge

        40%~60%

         

        Battery pack must be charged every three months when long term storage, please charge the battery pack with standard charging current for 0.5h~1h to keep 40%~60% state of charge.

        7.Charge the Battery Pack

        1) Please charge the battery pack with matched specified charger, and connect them in the way required by the specification of the charger.

        2) Do not cover anything over the battery pack when charging it, otherwise the heat will accumulate, that may cause declination of the performance of the battery pack and even cause leakage.

        3) Charge the battery pack at 0~45 degree.

        8. Warning and Caution

        WARNING !   

        1) Do not connect the battery pack's positive (+) and negative (-) poles reversed to charger or load, Do not connect the battery pack to charger's input power source (AC power supply).

        2) Do not let the battery pack's terminals (+ and -) contact with unnecessary wire or any metal or stored them together, that may cause the battery pack short-circuit.

        3) Do not drive a nail in battery pack, hit the battery pack with a hammer, stamp on or throw the battery pack.

        4) Do not disassemble or alter the batteries outside structure.

        5) Do not use the battery pack under blazing sun, otherwise may cause battery pack overheating then catch fire or disabler.

        6) Do not put the battery pack into fire or heat the battery pack; do not store the battery pack in high temperature environment

        7)  Do not submerge the battery pack in water or get wet in the rain, keep the battery in shady and cool place when stored.

        8) Do not charge the battery continuously over 24 hour.        

        9) Do not discharge the battery pack continuously when charging it.

        10) When charging or discharging the battery pack, if you find any abnormal smell or noise, you must stop the charging or discharging at once, and contact the manufactory.

        11) When using the battery pack out of range of 0~30 degree, the capacity may decrease, that doesn't mean the battery pack was failure.

        12There is a protective circuit inside the battery to prevent contingency. Do not use the battery in the Electro static circumstances, (above 1000V), for it is easily destroyed the circuit board so that the battery doses not work and causes over-heated, distort, smoke or burning.

         

        9.Warranty Period

        Guarantee is 25 months since it is out of the factory. Any damage by incorrect use and not quality problem, even in its guarantee period, free service won't be provided by the manufacture.

        10.Typical Fault and Exclusion Methods

        Fault Phenomenon

        Fault Possible Cause

        Exclusion Methods

        Battery pack no

        output

        Discharge wire not connected

        Connect discharge wire correctly

        The battery pack not released from discharge protect mode

         Switch off the battery pack for about 30S, then switch on it to release discharge protection

        The battery pack is empty

        Charge the battery pack

        Can't charge the

        battery pack

        Output plug of charger poor contact

        Ensure the output plug of charger firm contact with the battery pack

        The battery pack is fully charged

        The battery pack is ready to discharge

        Power indicate

        LED of charger

        Doesn't work

        Input plug of charger not connect to AC supply

        Connect input plug of charger to AC supply as specification required

        Remark: Any other fault, please contact with after-sale service department or dealer.

         

        11.Statement

        1) If the battery is used on other instruments or operating conditions than those described in this document, please contact with your manufacturer for how to get the best performance, at least consult its maximum current, fast charge and special application. Doctor Power will take no responsibility for any accident

        2) Doctor Power will take no responsibility for any accident when the battery pack is used under other conditions than those described in this Document.

        3) Doctor power will inform, in a written form, the customer of improvement(s) regarding proper use and handing of the battery pack, if it is deemed necessary.

        4)Doctor Power will take no responsibility for any accident when the battery pack is disassembled that isn't subject to Doctor power approval. 

        5)Please tell the parameters of the BMS or/and charger, If they aren't provided by Doctor Power. We will check the matchable quality between the BMS/charger and the battery. If you don't provide it, Doctor power will take no responsibility for any accident.

        6) The loss caused by force majeure should be implemented according to relevant laws and regulation

        7)Any of the matters not mentioned in the specification, subject to mutual consultation

        Please comfirm the specification timely after got it. If you haven't confirmed it after got specification within three days, it shows the default content of the specification.

         



copyright  2016-2025 Wuxi Doctor Power Technology Co.,Ltd  all right reserved  苏ICP备2023012393号-1
Site domain: www.doctor-power.com   E-mail:  kaidy@doctor-power.com